Is it time to brush up on the commissioning basics?


Hydronic system balancing is one of the more complicated tasks faced by building services engineers and historically heating and chilled water systems were balanced by specialist engineers only.

However, in recent years with advances in valve technology and the introduction of dynamic balancing products onto the market, there has been an increasing opportunity to simplify the process, cut costs and improve consistency – once the new technologies have successfully been adopted.

Albion has been a great advocate of demystifying the commissioning process and equipping engineers with the right tools and knowledge to help ensure the smooth running of their commissioning projects.

A lot has changed with valve technology in recent years, sometimes in this industry technology leaps forward so much that it leaves a skills gap as individual specifiers and engineers struggle to keep pace.

At Albion we really believe a back to basics approach works well and take the approach that system balancing should be as simple as possible.

The key to a successful commissioning project is to ensure the commissioning engineer is involved early in the decision making process. The commissioning process can be complex enough without an engineer having to inherit poor design and installation practices from the outset.

The wrong product selection, unnecessary inclusion and systems that have been inaccurately installed can cause an unnecessary headache.

Commissioning is not easy it is always squeezed in at the end of a contract. Being armed with better information early on and clarifying the application from start of design, can only be a good thing and ultimately save cost and time.

Les commented:

“Although products such as the Pressure Independent Control Balancing Valves (PICV) or Differential Pressure Control Valves (DPCV) are fast becoming standard in commissioning projects, not all heating engineers will be familiar and comfortable with using them, there is still work to be done with training and skills in this area.

We suggest using Albion’s guide Expert Ease as a refresher – it’s something engineers can refer back to. It shows some of the modern approaches and gives the user a chance to clarify, consider and also question what they find at commissioning time on installations.”

Expert Ease has been designed to ‘jargon bust’ and also simplify the process and support engineers in selecting the correct product and install in an appropriate location without expensive and time-consuming training.

Les added:

“In a nutshell commissioning really is all about balance. Balance in turn means a comfortable living and working environment for people using the building. With poor balance and control the system swings become too great, which causes extreme hot and cold temperature in our environment and ultimately energy wastage.”

PICVs help create a much narrower thermostatic range in heating systems, for example, which effectively stabilizes the temperature and reduces the likelihood of surges outside the comfort zone. Meaning the system does not work earlier than needed to deliver and can also reduce output sooner rather than overshoot the desired set-point temperature.

A properly balanced variable volume system can only be achieved with the correct set of dynamic balancing and control valves, these subsequently ensure the correct distribution of flow throughout the whole system irrespective of any pressure changes or the partial system load that will inevitably occur for the vast majority of the building’s operational life.

If the correct balancing of the system is not established, this will result in unequal distribution of the flow so that there will be a surplus effect in some of the terminals, while not enough in others consequently lowering the quality or comfort control.
The result of this will be that the desired heating or cooling will not be ensured in all parts of the installation.

Albion also recommends the use of DPCVs, which have proved to be extremely efficient in helping to stabilize the temperature in heating systems.

The DPCV is set to maintain a steady differential pressure, under dynamic balancing conditions, which ensures flow cannot exceed a desired rate. It therefore helps reduce both energy consumption and the risk of noisy vibrating pipes, while simplifying the commissioning process.

In addition, Thermostatic Radiator Valves (TRVs) are self-regulating and control the water that enters a radiator and ultimately help maintain a desired room temperature, TRVs come with lockable tamper proof temperature settings ideal for commercial environments.

Similarly in installations that require balance to be controlled in a specific location, e.g. one point of delivery to a room PICV can be used. These are particularly effective on air conditioning systems and chilled water terminal units e.g. fan coil units that can overheat the space or emit chilly blasts when over-circulating chilled water in the system.